Title: Coarse Stray Light Survey, 24um Array (CE1)
Performance Test 8.12


Analysis by: Vignesh Bhuvaneshwar (2 OCT 2000)

Summary: Darkest position is scanabs = 677


The average signal for each image was determined by a simple average for all scan mirror positions. The first DCE of each data set was ignored as the SUR mode currently does not function correctly for the first DCE. As a result, there are two points for each scan mirror position. The results are plotted below.




DATA: list (multiple, 10s, 3 DCE, stim)
Average brightness as a function of scan mirror position, and the average brightness for the left and the right half of the array are plotted.




Back to log sheet