Temperature and voltage ranges come from mission scenarios testing and serve as a reference for the sorts of temperature warmups that are normal in ground testing. Somewhat different temperature ranges are expected in the vacuum environment of space. query.CampA: K-0113 ERT EU %d CEState -- 1=Boot, 2=Operate K-0062 ERT EU %.4f SC Input Current -- plot (1070-1110), <>=1085+/-6 mA K-0061 ERT EU %.4f SC Input Voltage -- plot (30-31), <>=30.53+/-.04 V K-0058 ERT EU %.2f CEBoxTmp -- started at 22.5, climbed to 25.0K K-0056 ERT EU %.2f CPUTmp -- started at 24.3, climbed to 26.9K I-0130 ERT EU %.2f D160BoardTmp -- started at 32.3, climbed to 38.0K K-0060 ERT EU %.2f D70BoardTmp -- started at 16, climbed to 26.4K K-0057 ERT EU %.2f DataAcqTmp -- started at 27, climbed to 33.2K K-0051 ERT EU %.2f IOTmp -- started at 23, climbed to 28K (+/-.3K scatter) K-0052 ERT EU %.2f CSLVPSTmp -- started at 25, climbed to 32K K-0053 ERT EU %.2f IESLVPSTmp -- started at 26.5, climbed to 33.8K K-0054 ERT EU %.2f SiCntlTmp -- started at 26, climbed to 30K K-0055 ERT EU %.2f SiSigTmp -- started at 25, climbed to 31K