CAID: MIPS-280 | Title: Super Resolution of Proto-stellar Region | |
System: MIPS | Principal: krs | Deputy: alberto |
Objective: | Verify scientific validity of MIPS Photometry pipeline products. Source could be SVS-13 in HH 7-11 region. Possible ECO. |
Description: | Acquire normal photometry observations of an outflow region using the MIPS Photometry AOT in the Large Field mode. 3s @ 24 microns (15cycles), 3s @ 70 and 160 microns (15 cycles each), large field, fine scale @ 70 microns. Can be the same as: Evaluate fully supported AOTs (MIPS Photometry/SR) |
Day: 78.1770833333358 | Suggested Order: R800 | ||
Must be preceded by these activities (list by CAID): MIPS-320 | |||
Place in Schedule: After aperture door open After CTA/instrument cool down and all other instrument testing is complete. For 160um, the backgrd radiance must be less than 5.4E-13 W/cm2/sr (< 6 - 7 K). After Photometry AOT functionality testing is complete. Can be concurrent with other AOT/instrument tests. | |||
Priority: Necessary | |||
Conditions | |||
Maximum telescope temperature: | 6.5 K | ||
Minimum telescope temperature: | 5.5 K | ||
Should activity be repeated if focus changes? | No Repeat if focus changes by 0 mm | ||
Maximum absolute pointing uncertainty: | 1.4 arcsec (1 sigma radial) | ||
Maximum precision offset uncertainty: | 0.4 arcsec (1 sigma radial) | ||
Observatory configuration: | |||
Go/No Go criteria: | |||
Duration: 170 minutes
| Real time downlink:
 
No | |
Data Volume (uncompressed): 202 Mbits | |||
List Blocks, AORs, SERs, IERs, or unique sequences required (uplink): Standard pipeline system and standard data analysis tools required. MIPS Photometry/SR AOT required for uplink. | |||
List Analysis tools required (downlink): | |||
Estimate of data turn around: 0 hours | |||
Description: Fully calibrated MIPS Photometry data products in three bands. | |||
Can proceed in parallel with other activity: No | |||
Must outcome be confirmed before next activity: No | |||
Method of Confirmation: Data analysis | |||
Success criteria: | |||
Contingency plan: Revisit pipeline and/or AOT design depending on the nature of failure. | |||
Comments | |||
References: | |||
Additional Comments:
Required Conditions: CTA and instrument at nominal operating temperature for 160 micron band (mirror at 6 K). Note: This region has very bright IR sources -- this test can investigate how much of an impact there will be in an AOR. | |||
This activity last updated: 11/14/2001 11:57:53 AM |