Sequencer Site SIRTF IOC Activity c. 2002

CAID: MIPS-306 Title: 70 um IC - detailed, Scan AOR
 
System: MIPS Principal: aalonso Deputy: dfrayer
Objective:  
Acquire the data needed to produce
illumination-correction frames for the 70um 
array.  Enough DCEs (~30) are taken at each
scan-mirror deflection angle (33 positions) to
allow us to produce an illumination correction for
each scan-mirror  position. If these individual
flats are judged to be indistinguishable they can
be combined to create a single IC. Perform the
necessary data reduction (median-filtering) needed
to create the IC frames.
This activity is a companion to the ROUTINE Scan
and Photometry AOR illumination-correction
activities. These activities will allow us  to
determine the relative efficiency and quality of
flatfields created using scan and photometry AORs.
 
Description:
A 5-degree long x 3 legs scan map is taken using
the fast-scan AOT in a region of sky chosen to
avoid bright point-sources. The map will require
about 65.9 minutes of observing time.
 
Day:   68.2840277777868 Suggested Order:   Q100
 
Must be preceded by these activities (list by CAID):   MIPS-329, MIPS-915, MIPS-918
 
Place in Schedule:   Telescope temperature stable. MIPS temperature stable. CSMM operational. This task could possibly serve for both 70 and 160 um.
 
Priority:   Necessary


Conditions

Maximum telescope temperature: 12 K
 
Minimum telescope temperature: 5.5 K
 
Should activity be repeated if focus changes?   No     Repeat if focus changes by 0 mm
 
Maximum absolute pointing uncertainty: 3 arcsec (1 sigma radial)
 
Maximum precision offset uncertainty: 1 arcsec  (1 sigma radial)
 
Observatory configuration: standard
 
Go/No Go criteria: CSMM, CE, and stims and detectors must be operational, instrument and telescope temperatures must be stable


Resources

Duration:   65.9 minutes
 
Real time downlink:   No   

Data Volume (uncompressed): 810.1 Mbits
 
List Blocks, AORs, SERs, IERs, or unique sequences required (uplink): Scan AOR
 
List Analysis tools required (downlink):   standard pipeline

Outcome


Estimate of data turn around:   24 hours
 
Description: Illumination corrections for the 70 um array at all scan-mirror positions visited during scan operations.
 
Can proceed in parallel with other activity: No
 
Must outcome be confirmed before next activity: No
 
Method of Confirmation:   data analysis
 
 
Success criteria: ICs display no noticeable source residuals, have good S/N. Calibrated FPS and AOT validation data sets have source signal independent of postion in image.
 
Contingency plan:  Can use flats from ground-test data as a start; Must obtain good sky flats during IOC, though.
 
 

Comments

 
References:  
 
Additional Comments:
 
This activity last updated: 11/16/2001 1:54:29 PM