// THIS SECTION IS IN PHP. // ENTER CAID AND TITLE W/IN QUOTES IN THE FOLLOWING 2 LINES ... $caid="900"; // Don't mess w/ $file. $file = "mips-".$caid.".cookbook.php"; // END PHP. ?>
Principal: dmkellyif (file_exists("cookbook_header.php")) { include ("cookbook_header.php");} ?>
Deputy: cengelbracht
Data Monkey(s): Do Ball software engineers count as monkeys?
Priority: Necessary
Downlink Priority: Normal
Analysis Time: 24h
Last Updated: if (file_exists($file)) {echo date("D M d Y, H:i:s", filemtime($file) ) ;} ?>
1) Turn on power to the combined electronics 2) Transition from OFF to MIPS_OBSERVE 3) Perform thermal anneals on the Si array 4) Point the telescope to the first desired target 5) Before beginning the next IOC task, wait as necessary until 30 minutes has elapsed since the CE power-on
Diagnostic data will be collected during the 24um thermal anneal. 160 samples will be collected on 1s intervals. The items are: 1. D24TmpA 2. D24TmpB 3. D160TmpA 4. D24AnnealCur 5. D70TmpA 6. D160JnctTmp 7. D70BaseTmp 8. D160BaseTmp 9. D160StimTmp 10. CSMMTmp
CE_OFF_BOOT CE_BOOT_OPR MIPS_OPR_MRDY MIPS_MRDY_MOBS ColDiag_24TMP_MIPS Si_Anneal_Heat_MIPSA_MIPS DumpDiag_MIPS
Array Data Desired:
CECOLDIAG data from the anneal
Data Reformatting Option:
Special Instructions:
Step-by-step analysis: 1) Obtain the diagnostic data. This seemingly obvious step is called out because these data might not be delivered with the usual science data. They will not go through tranhead, nor through the SSC pipeline. 2) Generate plots of temperatures from all three thermal anneals and compare to ground test data. The necessary software is presented in the cookbook for mips-015, along with the ground test results. 3) The diagdump tool should be modified to allow overplotting of multiple anneal temperature profiles. Once the repeatability of the anneal profiles is developed, a master anneal profile should be developed to serve as a reference thereafter. At that point, the diagdump tool should be modified to always overplot the anneal profile with the master profile. 4) Record the pre-anneal and maximum temperatures for D24TmpA and D24TmpB in a table to be used for tracking during IOC. 5) If there are stability issues, gather up relevant telescope telemetry and look for correlations.