Sequencer Site SIRTF IOC Activity c. 2002

CAID: MIPS-914 Title: 24 um Flat - routine, Scan AOR
 
System: MIPS Principal: aalonso Deputy: sstolovy
Objective:  
To obtain IOC acceptable 24um scan flat fields to
be used on a regular basis. This activity is a
companion to the 24 um Flat ROUTINE Phot AOR. The
pair of activities will allow us to determine the
relative efficiency and quality of flatfields
created using scan and photometry AORs.
 
Description:
A 2 degree long (1 leg) scan map will be obtained
using the fast-scan AOT in a region of the sky
chosen to avoid bright point sources. This will
produce a total of 118 images to be median
combined to produce a 24 um flat. The map will
require about 12.7 minutes of observing time.
 
Day:   48.149305555562 Suggested Order:  
 
Must be preceded by these activities (list by CAID):   MIPS-329
 
Place in Schedule:   MIPS CE, CSMM, stim operation nominal. CTA temperature within range, and MIPS temperature stable. 24um background falls below 1% of 25MJy/sr, the medium sky background level, at 25K, so it should be possible to obtain good dat a for this activity for CTA temperatures below that even if the CTA temperature is changing.
 
Priority:   Critical


Conditions

Maximum telescope temperature: 33 K
 
Minimum telescope temperature: 5.5 K
 
Should activity be repeated if focus changes?   No     Repeat if focus changes by 0 mm
 
Maximum absolute pointing uncertainty: 3 arcsec (1 sigma radial)
 
Maximum precision offset uncertainty: 1 arcsec  (1 sigma radial)
 
Observatory configuration: standard
 
Go/No Go criteria: CSMM, CE, and stims and detectors must be operational, instrument and telescope temperatures must be stable


Resources

Duration:   13 minutes
 
Real time downlink:   No   

Data Volume (uncompressed): 120.5 Mbits
 
List Blocks, AORs, SERs, IERs, or unique sequences required (uplink): Use scan map AOTS.
 
List Analysis tools required (downlink):   standard pipeline

Outcome


Estimate of data turn around:   24 hours
 
Description: A 24 um flatfield for scan AORs.
 
Can proceed in parallel with other activity: No
 
Must outcome be confirmed before next activity: No
 
Method of Confirmation:   data analysis
 
 
Success criteria: Flats/I.C.s display no noticeable source residuals, have good S/N. Flattened/I.C.d FPS and AOT validation data sets have source signal independent of position in image.
 
Contingency plan: 
 
 

Comments

 
References:  
 
Additional Comments:
 
This activity last updated: 11/19/2001 12:16:03 PM