Red Alarm Analysis, MIPS Campaign A

Analysts:  Tom Glenn and Douglas Kelly
Last Updated:  9/9/03

MIPS registered a large number of red alarms during campaign A.
The following is a detailed review of these alarms.

A large number of alarms appeared at time 03-245T01:21:47.230. This
coincides with the OFF_BOOT state transition.  There is a short
time during this state transition when the CEState is indeterminate,
the telemetry values are invalid, and a large number of false red 
alarms appears.  The same is true during the BOOT_OPR transition 
at 03-245T01:26:11.230, the MIPS_OPR_MRDY transition at 03/245-01:32:55.328,  
and the MIPS_MRDY_OPR state transition at 03/245-02:57:19.289.  I do
not have the timestamps for the OPR_BOOT transition during Campaign A2,
but false telemetry was expected at that time as well.  The comments
below include information on when each of the telemetry values is valid.
These conditions should be incorporated into the alarm-checking software
to reduce the number of false alarms.  The alarms addressed by these 
state transition invalid telemetry episodes are:


I-0100 U D70OfstV_B     (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0100 
          U D70OfstV_B   -5.10088e+00            0 REDLOW   -1.000e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0104 U D70m5RefV      (2 alarm entries found)
          First Entry:  746933596.   03/245-01:33:03.289  MIPS I-0104 
          U D70m5RefV    -4.28950e-03        32738 REDHIGH  -4.960e+00
          Last  Entry:  746938648.   03/245-02:57:15.328  MIPS I-0104 
          U D70m5RefV    -4.44518e-03        32737 REDHIGH  -4.960e+00
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0105 U D70ILoadV      (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0105 
          U D70ILoadV     1.02018e+01            0 REDHIGH   4.000e-02
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0106 U D70AnalogRtn   (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0106 
          U D70AnalogRtn -5.10088e+00            0 REDLOW   -5.000e-02
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0107 U CSM_PosOut     (2 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0107 
          U CSM_PosOut   -3.38934e+04            0 REDLOW         5587
          Last  Entry:  746933592.   03/245-01:32:59.289  MIPS I-0107 
          U CSM_PosOut   -3.38934e+04            0 REDLOW         5587
Comments:
Only valid when I-0028 (CSM_DriveEn) = Enable

I-0110 U CSM_Current    (2 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0110 
          U CSM_Current  -3.40292e+04            0 REDLOW   -2.100e+04
          Last  Entry:  746933592.   03/245-01:32:59.289  MIPS I-0110 
          U CSM_Current  -3.40292e+04            0 REDLOW   -2.100e+04
Comments:
Only valid when I-0028 (CSM_DriveEn) = Enable

I-0114 U D160OfstV_B    (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0114 
          U D160OfstV_B  -5.10088e+00            0 REDLOW   -1.000e-01
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0120 U D160IloadV     (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0120 
          U D160IloadV    1.02018e+01            0 REDHIGH   4.000e-02
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0121 U D160m5RefV     (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0121 
          U D160m5RefV   -5.10088e+00            0 REDLOW   -5.040e+00
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0124 U D70AnHtrCur    (2 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0124 
          U D70AnHtrCur   3.38562e+01            0 REDHIGH   2.000e+01
          Last  Entry:  746933592.   03/245-01:32:59.289  MIPS I-0124 
          U D70AnHtrCur   3.38562e+01            0 REDHIGH   2.000e+01
Comments:

I-0126 U D160AnHtrCur   (2 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0126 
          U D160AnHtrCur  3.38562e+01            0 REDHIGH   2.600e+01
          Last  Entry:  746933592.   03/245-01:32:59.289  MIPS I-0126 
          U D160AnHtrCur  3.38562e+01            0 REDHIGH   2.600e+01
Comments:

I-0128 U D160QrstHiV    (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0128 
          U D160QrstHiV   3.60093e+00            0 REDHIGH  -1.480e+00
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0200 U D160DetBiasV   (2 alarm entries found)
          First Entry:  746933596.   03/245-01:33:03.289  MIPS I-0200 
          U D160DetBiasV  7.25160e-01        32821 REDHIGH   3.010e-01
          Last  Entry:  746938648.   03/245-02:57:15.328  MIPS I-0200 
          U D160DetBiasV  7.27807e-01        32804 REDHIGH   3.010e-01
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0201 U D160RstDV1     (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0201 
          U D160RstDV1    4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0203 U D160RstDV3     (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0203 
          U D160RstDV3    4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0204 U D160RstDV4     (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0204 
          U D160RstDV4    4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0210 U D70DetBiasV    (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0210 
          U D70DetBiasV   5.83464e+00            0 REDHIGH   3.010e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0211 U D70RstDV1      (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0211 
          U D70RstDV1     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0212 U D70RstDV2      (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0212 
          U D70RstDV2     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0214 U D70RstDV4      (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0214 
          U D70RstDV4     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0215 U D70RstDV5      (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0215 
          U D70RstDV5     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0217 U D70RstDV7      (1 alarm entries found)
          Alarm Entry:  746933588.   03/245-01:32:55.328  MIPS I-0217 
          U D70RstDV7     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0218 U D70RstDV8      (1 alarm entries found)
          Alarm Entry:  746933592.   03/245-01:32:59.289  MIPS I-0218 
          U D70RstDV8     4.36711e+00            0 REDHIGH  -7.138e-01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

K-0037 U D70JnctTmp     (1 alarm entries found)
          Alarm Entry:  746933600.   03/245-01:33:07.285  CE   K-0037 
          U D70JnctTmp    1.47154e+01        32775 REDHIGH   5.000e+00
Comments:
Only valid when I-0363 (TmpSensEn) = Enable

K-0039 U D70BaseTmp     (1 alarm entries found)
          Alarm Entry:  746938648.   03/245-02:57:15.328  CE   K-0039 
          U D70BaseTmp    1.52857e+01        32731 REDHIGH   7.000e+00
Comments:
Only valid when I-0363 (TmpSensEn) = Enable

K-0040 U D160BaseTmp    (1 alarm entries found)
          Alarm Entry:  746938652.   03/245-02:57:19.289  CE   K-0040 
          U D160BaseTmp   1.49569e+01        32748 REDHIGH   7.000e+00
Comments:
Only valid when I-0363 (TmpSensEn) = Enable

K-0059 U D24StimCur     (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0059 
          U D24StimCur    1.80090e+04            0 REDHIGH   6.750e+03
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0059 
          U D24StimCur    1.80090e+04            0 REDHIGH   6.750e+03
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0061 U SCInputVolt    (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0061 
          U SCInputVolt  -6.27820e+01            0 REDLOW    2.000e+01
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0061 
          U SCInputVolt  -6.27820e+01            0 REDLOW    2.000e+01
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0063 U CS5V           (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0063 
          U CS5V         -1.24810e+01            0 REDLOW    4.600e+00
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0063 
          U CS5V         -1.24810e+01            0 REDLOW    4.600e+00
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0064 U IES5V          (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0064 
          U IES5V        -1.24810e+01            0 REDLOW    4.500e+00
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0064 
          U IES5V        -1.24810e+01            0 REDLOW    4.500e+00
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0065 U IES15V         (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0065 
          U IES15V       -2.12290e+01            0 REDLOW    1.350e+01
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0065 
          U IES15V       -2.12290e+01            0 REDLOW    1.350e+01
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0066 U IESm15V        (2 alarm entries found)
          First Entry:  746932920.   03/245-01:21:47.230  CE   K-0066 
          U IESm15V      -2.12290e+01            0 REDLOW   -1.650e+01
          Last  Entry:  746933184.   03/245-01:26:11.230  CE   K-0066 
          U IESm15V      -2.12290e+01            0 REDLOW   -1.650e+01
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0067 U SiDet5VDRef    (2 alarm entries found)
          First Entry:  746932920.   03/245-01:21:47.230  CE   K-0067 
          U SiDet5VDRef  -1.24810e+01            0 REDLOW    4.600e+00
          Last  Entry:  746933184.   03/245-01:26:11.230  CE   K-0067 
          U SiDet5VDRef  -1.24810e+01            0 REDLOW    4.600e+00
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0068 U SLHeaterCur    (2 alarm entries found)
          First Entry:  746932920.   03/245-01:21:47.230  CE   K-0068 
          U SLHeaterCur   2.07197e+02            0 REDHIGH   1.370e+02
          Last  Entry:  746933184.   03/245-01:26:11.230  CE   K-0068 
          U SLHeaterCur   2.07197e+02            0 REDHIGH   1.370e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0069 U SHHeaterCur    (2 alarm entries found)
          First Entry:  746932920.   03/245-01:21:47.230  CE   K-0069 
          U SHHeaterCur   2.07197e+02            0 REDHIGH   1.370e+02
          Last  Entry:  746933184.   03/245-01:26:11.230  CE   K-0069 
          U SHHeaterCur   2.07197e+02            0 REDHIGH   1.370e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0070 U LLHeaterCur    (2 alarm entries found)
          First Entry:  746932920.   03/245-01:21:47.230  CE   K-0070 
          U LLHeaterCur   1.75863e+02            0 REDHIGH   1.100e+02
          Last  Entry:  746933184.   03/245-01:26:11.230  CE   K-0070 
          U LLHeaterCur   1.75863e+02            0 REDHIGH   1.100e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0071 U LHHeaterCur    (2 alarm entries found)
          First Entry:  746932924.   03/245-01:21:51.230  CE   K-0071 
          U LHHeaterCur   1.75863e+02            0 REDHIGH   1.100e+02
          Last  Entry:  746933188.   03/245-01:26:15.234  CE   K-0071 
          U LHHeaterCur   1.75863e+02            0 REDHIGH   1.100e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0072 U D24HeaterCur   (2 alarm entries found)
          First Entry:  746932924.   03/245-01:21:51.230  CE   K-0072 
          U D24HeaterCur  2.40317e+02            0 REDHIGH   1.060e+02
          Last  Entry:  746933188.   03/245-01:26:15.234  CE   K-0072 
          U D24HeaterCur  2.40317e+02            0 REDHIGH   1.060e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0073 U IRSStimCur     (2 alarm entries found)
          First Entry:  746932924.   03/245-01:21:51.230  CE   K-0073 
          U IRSStimCur    1.42000e+03            0 REDHIGH   5.600e+02
          Last  Entry:  746933188.   03/245-01:26:15.234  CE   K-0073 
          U IRSStimCur    1.42000e+03            0 REDHIGH   5.600e+02
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0074 U SiSig5VARef    (2 alarm entries found)
          First Entry:  746932924.   03/245-01:21:51.230  CE   K-0074 
          U SiSig5VARef   1.26060e+01            0 REDHIGH   5.400e+00
          Last  Entry:  746933188.   03/245-01:26:15.234  CE   K-0074 
          U SiSig5VARef   1.26060e+01            0 REDHIGH   5.400e+00
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0107 S WatchDogBark   (1 alarm entries found)
          Alarm Entry:  746932924.   03/245-01:21:51.230  CE   K-0107 
          S WatchDogBark       Silent           00 REDMASK  0X00000001
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0108 S IESStatus      (1 alarm entries found)
          Alarm Entry:  746932924.   03/245-01:21:51.230  CE   K-0108 
          S IESStatus             Off           00 REDMASK  0X00000001
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

K-0255 S LimCheckStat   (2 alarm entries found)
          First Entry:  746932916.   03/245-01:21:43.234  CE   K-0255 
          S LimCheckStat      Disable           00 REDMASK  0X00000001
          Last  Entry:  746933180.   03/245-01:26:07.238  CE   K-0255 
          S LimCheckStat      Disable           00 REDMASK  0X00000001
Comments:
Power On transient. Submitted Red Alarm Update Form to update persistence to 3.

-----------------------------------------------------------------------------
K-1088 U AnD24AnnealC   (1083 alarm entries found)
          First Entry:  746935662.   03/245-02:07:29.762  CE   K-1088 
          U AnD24AnnealC  1.12092e+03        18512 REDHIGH   7.620e+02
          Last  Entry:  746938157.   03/245-02:49:04.355  CE   K-1088 
          U AnD24AnnealC  1.06787e+03        19181 REDHIGH   7.620e+02
Comments:
This item should be removed from the telemetry verification list.  The
red alarm appears because of stale telemetry.  The use of ancillary 
telemetry is not helpful because we never collect science data while
the anneal heater is active.

------------------------------------------------------------------------------

For the following 4 telemetry items, the out-of-limits conditions are real,
and they are expected based on the very bright background conditions.  In
these bright light conditions, the Ge detector arrays quickly reach saturation
and the unit cell current draw drops precipitously.  This condition should 
remedy itself as we approach the 70um first light campaign.  These telemetry 
items are critically diagnostic of other problems, so we want to keep them 
in the alarm list.  We also wish to retain the current red limits levels 
with the awareness that these telemetry items will be out-of-limits in the 
early MIPS campaigns.  These alarms are not related to the 70um readout 44
problem.

I-0101 U D70DucCurA     (1220 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0101 
          U D70DucCurA    4.22790e+02            0 REDHIGH   2.250e+02
          Last  Entry:  746938652.   03/245-02:57:19.289  MIPS I-0101 
          U D70DucCurA   -1.28407e+03        32688 REDLOW    2.000e+01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-0102 U D70DucCurB     (1227 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0102 
          U D70DucCurB    3.94121e+02            0 REDHIGH   2.250e+02
          Last  Entry:  746938652.   03/245-02:57:19.289  MIPS I-0102 
          U D70DucCurB   -1.29793e+03        32713 REDLOW    2.000e+01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-1101 U AnD70DucCurA   (781 alarm entries found)
          First Entry:  746935662.   03/245-02:07:29.762  MIPS I-1101 
          U AnD70DucCurA  1.32020e+01         7844 REDLOW    2.000e+01
          Last  Entry:  746938157.   03/245-02:49:04.355  MIPS I-1101 
          U AnD70DucCurA  1.35675e+01         7837 REDLOW    2.000e+01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

I-1102 U AnD70DucCurB   (877 alarm entries found)
          First Entry:  746935662.   03/245-02:07:29.762  MIPS I-1102 
          U AnD70DucCurB  1.22931e+01         7382 REDLOW    2.000e+01
          Last  Entry:  746938157.   03/245-02:49:04.355  MIPS I-1102 
          U AnD70DucCurB  1.27586e+01         7373 REDLOW    2.000e+01
Comments:
Only valid when I-0022 (D70PowerEn) = PowerOn

------------------------------------------------------------------------------
Careful examination of the following two items shows that the only times
that they are out-of-limits is during the startup and shutdown telemetry
transients.

I-0111 U D160DucCurA    (5 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0111 
          U D160DucCurA   4.60809e+02            0 REDHIGH   1.000e+02
          Last  Entry:  746938652.   03/245-02:57:19.289  MIPS I-0111 
          U D160DucCurA  -1.28902e+03        32546 REDLOW   -1.400e+02
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

I-0112 U D160DucCurB    (5 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  MIPS I-0112 
          U D160DucCurB   4.36366e+02            0 REDHIGH   1.000e+02
          Last  Entry:  746938652.   03/245-02:57:19.289  MIPS I-0112 
          U D160DucCurB  -1.28931e+03        32549 REDLOW   -1.400e+02
Comments:
Only valid when I-0023 (D160PowerEn) = PowerOn

------------------------------------------------------------------------------

I-1110 U AnCSM_Curr     (649 alarm entries found)
          First Entry:  746935662.   03/245-02:07:29.762  MIPS I-1110 
          U AnCSM_Curr   -1.63798e+04        16994 REDLOW   -2.100e+03
          Last  Entry:  746937765.   03/245-02:42:32.727  MIPS I-1110 
          U AnCSM_Curr   -6.15300e+03        26841 REDLOW   -2.100e+03
Comments:
The REDLOW limit should be -2.100e+04, not +03.

------------------------------------------------------------------------------

K-0035 U D24TmpA        (23 alarm entries found)
          First Entry:  746933596.   03/245-01:33:03.289  CE   K-0035 
          U D24TmpA       5.45257e+01        32754 REDHIGH   1.000e+01
          Last  Entry:  746938648.   03/245-02:57:15.328  CE   K-0035 
          U D24TmpA       5.45339e+01        32753 REDHIGH   1.000e+01
Comments:
Only valid when K-0334 (D24SiTmpSen) = Enabled

K-0036 U D24TmpB        (23 alarm entries found)
          First Entry:  746933596.   03/245-01:33:03.289  CE   K-0036 
          U D24TmpB       5.29750e+01        32765 REDHIGH   1.000e+01
          Last  Entry:  746938648.   03/245-02:57:15.328  CE   K-0036 
          U D24TmpB       5.30833e+01        32752 REDHIGH   1.000e+01
Comments:
Only valid when K-0334 (D24SiTmpSen) = Enabled

K-0041 U D70TmpA        (6 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  CE   K-0041 
          U D70TmpA       1.55126e+01        32740 REDHIGH   5.000e+00
          Last  Entry:  746938652.   03/245-02:57:19.289  CE   K-0041 
          U D70TmpA       1.56471e+01        32732 REDHIGH   5.000e+00
Comments:
Only valid when K-0363 (TmpSensEn) = Enabled

K-0042 U D70TmpB        (6 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  CE   K-0042 
          U D70TmpB       1.58889e+01        32749 REDHIGH   5.000e+00
          Last  Entry:  746938652.   03/245-02:57:19.289  CE   K-0042 
          U D70TmpB       1.60222e+01        32743 REDHIGH   5.000e+00
Comments:
Only valid when K-0363 (TmpSensEn) = Enabled

K-0043 U D160TmpA       (6 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  CE   K-0043 
          U D160TmpA      1.49132e+01        32733 REDHIGH   5.000e+00
          Last  Entry:  746938652.   03/245-02:57:19.289  CE   K-0043 
          U D160TmpA      1.49434e+01        32729 REDHIGH   5.000e+00
Comments:
Only valid when K-0363 (TmpSensEn) = Enabled

K-0045 U D160TmpB       (6 alarm entries found)
          First Entry:  746933588.   03/245-01:32:55.328  CE   K-0045 
          U D160TmpB      1.48974e+01        32746 REDHIGH   5.000e+00
          Last  Entry:  746938652.   03/245-02:57:19.289  CE   K-0045 
          U D160TmpB      1.49915e+01        32735 REDHIGH   5.000e+00
Comments:
Only valid when K-0363 (TmpSensEn) = Enabled